Very low emission conductive linoleum adhesive with a high initial grab.
Basis | : | Superior acrylic dispersion. |
Colour | : | Grey. |
Consistency | : | Thick liquid. |
Product advantages:
Very low emission
Emicode EC 1 plus
Non-flammable
Easy and safe to apply
High initial adhesion strength
Favourable spreading capacity
Roller-castor-chair resistant
Electrical resistance < 3.105 Ohm (EN 13 415)
Consumption | : | 260 - 300 g/m². |
Electrical resistance | : | < 3.105 Ohm, measured in accordance with EN 13 415. |
Flammability | : | Non-flammable. |
Specific weight | : | 1.13 kg/l. |
Application:
For the conductive installation of:
conductive linoleum.
For an optimal conduction apply 615 Eurostar Lino EL in combination with 041 Europrimer EL and 801 Copper strip. Before application read the technical data sheet of 041 Europrimer EL and 801 Copper strip.
Storage | : | Store cool and free from frost. |
Tools | : | Adhesive spreader TKB S2. (is included) |
Open time | : | 10-20 minutes.* |
Latency | : | None. |
Drying time | : | 24 hours.* |
Shelf Life | : | 12 months, in unopened packaging. |
Frost-proof | : | No. |
* The mentioned values have been established in our laboratory and must be considered as guidelines in view of possible variations in climatic circumstances, subfloor compositions and layer thickness.
Consumption:
260 - 300 g/m².
Substrate:
615 Eurostar Lino EL is suitable for any type of subfloor that has a good tensile and compression strength. The subfloor should also be even, clean, permanently dry and free from grease and dirt, according to the requirements of BS 8203 of DIN 18 365.
On impervious subfloors apply a 2 mm levelling compound layer.
In advance always seek our technical data sheets. In doubt about the application ask for technical advice
User manual:
Working conditions:
Required surrounding temperature : 18 - 23 °C.
Temperature for material and subfloor : min. 15° - max. 20 ºC.
Relative humidity : 40 - 80%.
Directions for use:
Apply the adhesive with a large-notched adhesive spreader (TKB S2).
On absorbent subfloors apply the floor covering directly into the wet adhesive. On low absorbent subfloors keep a waiting time of 10-30 minutes (depending on temperature and relative humidity).
Do not double-stick bight marks. Lay bight marks into the wet adhesive as usual. Thereafter roll the floor covering well; first widthwise, then lengthwise.
Sheet-ends, possible bight marks and longitudinal joints are to be pressed firmly.
On low absorbent subfloors rolling and pressing should be repeated after approx. 15 minutes.
Remove fresh adhesive spots immediately with water.
Underfloor heating systems:
615 Eurostar Lino EL can be applied on underfloor heating systems. The start protocol of the floor heating needs to be completely executed in accordance with the directives of the supplier. Turn off the heater 24 hours before application. Do not heat again until at least 24 hours after installation, in steps of maximum 5 °C water temperature per day.
Contains methylchloroisothiazolinone and methylisothiazolinone (3:1) and benzisothiazolinone. May produce an allergic reaction.